Pyrogen IPEX Bus Fire Suppression System 7T

200,000.00

Category:

Designation:
The Pyrogen IPEX-7T is a dual-action impulse extinguishing module containing ABC dry chemical powder and a gas-aerosol generator.
It is designed for fires in various classes, including flammable solids, liquids, gases, and fires involving electrical equipment up to 1,000 Volts.
Not suitable for fires involving alkali and alkali-earth metals or materials that combust without air admission.

Main Parameters:
Module Capacity: 7.8 ± 0.5 L
Mass of Full Module: 13 ± 0.5 kg
Discharge Time: Not more than 5 seconds
Activation Time: Not more than 10 seconds
Electrical Parameters: Activation current 0.4 Amp, circuit resistance 3.0 to 6.5 Ohms, safe monitoring current not more than 0.01 Amp, max activation current 3.0 Amp, duration of applied electrical activation current not less than 0.1 seconds.
Minimum Service Life on Transport: Not less than 5 years

Supply:
Each Pyrogen IPEX-7T module supply includes the module itself, electrical actuator, and electrical connector.

Construction & Operation Principle:
The module is a non-pressurized device with a steel casing, ABC extinguishing powder, gas-aerosol generator, and an electrical actuator.
It operates when an electrical current is applied to the electrical actuator, activating the gas-aerosol generator and releasing a gas-aerosol 3-dimensional mixture to suppress the fire.

Safety Measures:
Installation and servicing should only be conducted by accredited personnel.
Avoid connecting the module to any power source before installation.
Ensure the module is electrically disconnected before conducting any work in the protected area.
Adhere to safety measures during cleanup procedures following a system discharge.

Design & Installation:
The module can be installed inside or outside the protected space and is mounted on the wall or a vertical section of the mounting structure.
Installation and mounting should be conducted in consultation with the owner or operator, considering discharge nozzles and their orientation.

Maintenance:
Conduct a visual inspection for damages and alterations monthly.
Inspect the electrical detection and activation circuit, insulation, connection joints, and discharge nozzles regularly.

Service Life:
The service life of IPEX-7T on transport and mobile equipment is 5 years from the date of installation.